HDPE Corrugated Pipe Installation Examples
Comparative Analysis of Project Costs
|
PROJECT
|
LOCATION
|
DESCRIBDION
|
PIPE USED
|
COST SAVINGS VS. CONCRETE
|
| Orlando Intl. Airport (Parking facility) |
Orlando, FL |
Storm Sewer System |
12" - 36" HDPE pipe |
$31,000 |
| Atlanta's Hartsfield Intl. Airport |
Atlanta, GA |
Retention/detention system |
15" - 48" HDPE pipe |
30-50% |
| Target Storm |
Jacksonville, NC |
Sewer System |
HDPE pipe |
25% or $35,250 |
| Wal-Mart Super Center |
Pensacola, FL |
Storm Sewer System |
12" - 48" HDPE pipe |
40% or $20,900 |
| NYSDOT |
Guilderland, NY |
Storm Sewer System |
18" - 36" HDPE pipe |
$21,308 |
| Ardmore High School |
Bowie, MD |
Storm Sewer System |
12" - 36" HDPE pipe |
$16,270** |
* Compiled from individual
reports. On all projects, concrete pipe and corrugated polyethylene pipe
were allowed materials.
** Does not include reduced costs for installation.
Comparative Analysis of Pipe Material
| |
 |
 |
 |
| SPECIFICATIONS |
AASHTO M252, ASTM F405 AASHTO M294, ASTM F667 AASHTO
MP7, CAN CSA-182.6, CPPA 100 Standard Spec. |
12" - 36" HDPE pipe |
ASTM A760, AASHTO M36 |
| JOINTS |
-Silt tight through watertight capabilities - 60%
fewer joints than concrete |
-Gaskets available - May require steel joint rings
for water tightness |
-External bolted bands required |
| WATER TIGHT PERFORMANCE |
-F477 rubber gaskets provide lower leakage rates
in industry |
-Leakage rates 200 gal/in. dia/mi/day |
-Leakage rates >200 gal/in. dia/mi/day |
| DURABILITY |
-Excellent chemical and abrasion resistance |
-HDPE or PVC linings used to enhance service life,
and/or reduce abrasion - Susceptible to corrosion from road salts
and chemicals |
Special coatings and/or increased steel thickness
can be used to enhance service life |
| HYDRAULICS |
Typical Mannings "n" design values of .013 (Published
test values as low as .009) |
Typical Mannings "n" design values of .013 (Published
test values as low as .010) |
Typical Mannings "n" design values of .013 (Published
test values as low as .0111) |
| STRUCTURAL |
-Capable of live load traffic (H-20) at 1 foot of
min. cover and (E-80) at 2 feet min. cover-Standard product capable
of deep burial applications. |
-Standard strength classes available - Spigot reinforcing
may be required to prevent joint shear |
Standard gauge thickness available |
| DIAMETERS |
3" - 60"
|
8" - 144" (Some small diameters have no reinforcement) |
4" - 144"
|
Other Information:
Corrugated Pipe Installation
Guidelines |